| Karl Fischer Moisture Titrator |
| |
|
| |
Microcoulometric Method Water Detector (double coulomb)  |
| CA-100 Micro-moisture Analyzer could analyze samples such as liquid, solid, and gas substances, as well as detect the bromine value and bromine index. Proper water carburettors could be selected to connect with CA-100 Micro-moisture Analyzer. |
| Technical parameters:
- Electrolytic current: Maximum 400mA
- Titration speed: Maximum 2.1mgH2O/min
- Analytical range: 10ug~100mgH2O
- Sensitivity: 0.1ugH2O
- Precision: ±3ug(10ug~100mgH2O)RSD0.3% or less(1mg or more H2O)
- Printer: 21-Pin Dot Matrix Printer (paper 58mm wide)
|
 |
 |
|
| |
Volumetric Method Minim Moisture Analyzer (single tube capacity)  |
| KF-100 Micro-moisture Analyzer could analyze samples such as liquid, solid, and gas substances, and if some accessories are selected, more functions could be added. It also can select single channel (single tube capacity, double tube capacity), double channels (double-single tube channel) |
Technical parameters:
- Titration range: electrolytic potential proportion control
- Analytical range: 0.1~999mgH2O
- Recurrence: ±0.01mgH2O
- Printer: 21-Pin Dot Matrix printer (paper 58mm wide)
|
 |
 |
|
| |
Automatic Titrator  |
GT-100 Automatic Titrator is a convenient and reliable general analytical device for the laboratories. Controlled by computer, it can accurately detect the titration end and print the analytical result and graph in a short time. It is applied in all kinds of inorganic and organic titration analysis, acid-base titration, oxido-reduction potential titration, complexometric titration,non-aqueous solution titration, photometric titration, precipitation titration and etc. It can store eight titration documents, and it is easy to operate. It has unique control system, and its titration amount change automatically with the electric level so that it can accurately identify the inflexion. It can set standard concentration calculation formula or user’s special formula, and it can also conduct concentration calculation when there are two or more inflexions. Since the titration data is stored in the machine, re-analysis could be conducted when the parameters are revised after the detection.
The titration tubes of the GT-100 are designed by units and they are easy to be replaced. One machine can be connected with four titration tubes, and it can conduct multi-reagent titration. After it connects with the automatic sampling switcher, GT-100 can detect eight different samplers in succession and high byte computer, and can connect with electric scale so as to realize the automation of data management.
The optional parts of GT-100 also include all types of TVs, FPDs, printers, Karl Fischer Moisture Titrator, and etc. |
Technical parameters:
- Titration method: Potentiometric Titration
- Control method: Automatic control titration amount
- End detection: Pre-set end potential or pre-set inflexion
- Display: 20 digits, LCD display
- Calculation function: Automatic concentration calculation (eight formulas); statistical calculation; automatic pH emendation.
- Printer: 21-pin dot heat sensitive matrix printer
- Titration tube: Standard 20 ml, scale 2 microlitre, precision ±0.02 ml
- Stirrer: electromagnetic stirring 0-800 r/min
- Titration model: trial titration, sample titration, reagent standard titration, static titration, and KFT.
|
 |
 |
| |
|
|
|