| Special Chromatography and its Accessories |
| |
|
| |
DK3001 Headspace Chromatogram Alcohol Analyzer  |
| Drunk driving seriously violates the traffic rules of China , and whether the driver is drunk driving is one of the important basis for identifying the responsibilities of the accidents when handling the traffic accidents. Headspace chromatogram method is adopted worldwide to accurately detect the alcohol contents in driver's blood. However, since the price of the imported equipment is too expensive, it is impossible for this kind of equipment being applied in low-level traffic police stations. With reference to the similar products produced in other countries and based on the real situation of China , by take years research and development, the company has developed the DK3001 Headspace Chromatogram Alcohol Analyzer. With its high sensitivity, fast analyzing speed, and stable operation, it can accurately detect the alcohol content in human's blood just within two minutes. This machine has been widely applying in the public security system. Its effect is obvious and highly appraised by the users. Our company are willing to become your reliable friend by providing your high quality products and services. |
| |
|
DK3001 Headspace Chromatogram Alcohol Analyzer
It consists of the following parts:
1. Headspace Sampler Technical Parameters
- Headspace bottle heating temperature: 75 ℃
- Injection valve heating temperature: 90 ℃
- Samples transmission pipe temperature: 90 ℃
- Quantification tube capacity: 1ml
- Headspace bottle spec: 10ml
|
 |
2. GC9900 Gas Chromatography Features:
- Digital control, Chinese keyboard, easy to operate
- LCD screen, and it can display several group of parameters at the same time
- Four routes temperature control, two level temperature programming, and automatic back door
- Chromatogram column temperature: 120 ℃
- Injector temperature: 150 ℃
- Detector temperature : 180 ℃
- Detector sensitivity: 8×10-12 g/s (n 16)
|
 |
3. Special chromatogram data workstation technical parameter
- 24 byte external gathering unit
- WINDOWS98/2000 operation interface
- Lenovo P4 computer
- Laser printer
|
 |
4. GX-300 Nitrogen, Hydrogen, & Air Generator Technical parameters
Gas flowrate
- Nitrogen flowrate: 0-300ml/min
- Hydrogen flowrate: 0-300ml/min
- Air flowrate: 0-2000ml/min
Gas Pressure:0-0.4Mpa
Power:220V±10% 50/60Hz
Maximum power:450W
Dimension:500×430×380
Wight:40Kg |
 |
| |
|
 |
|
| |
|
Logging Gas Chromatography  |
| Logging gas chromatography is a new type special chromatography developed and designed on the basis of introducing and assimilating GC3400 manufacturing technology from American Varian Company, and it keeps all the functions of GC3400 gas chromatography. The machine adopts packed column, quartz capillary multidimensional column, valve switch systems, and a single injection can conduct fast analysis on C1-C4 and other ingredients. Its analysis speed is fast, it can finish the analysis on C1-C4 within two minutes.
The machine adopts the latest automatic switch valve design. The valve is easy to operate, and without extra-column volume effect and only one valve operation is required for each analytical cycle so that it reduces the times of the operation. Thus, the valve’s life-span could reach over 100000 times. There are four external event program operations, and all valves and the detector signals are automatically switched by the pre-set programs.
It can work with all kinds of common chromatogram data workstations and conduct fast computation on the chromatogram. The original data could be stored permanently and it could be accessed and reprocessed at any time. |
| Technical parameters:
- Column box tem temperature: above room temperature (20-350℃)
- Temperature programming: 1-4 level linear temperature programming can be set, the rate is 0.1-50℃/min.
- Detector temperature: above room temperature (20-350℃)
- Injector temperature: above room temperature (20-350℃)
- Valve box temperature: 50℃
- TCD sensitivity: ≥5000mvml/mg(sample butane)
- FID detecting limit:≤8×10-12g/s(N-C16)
- Ingredients to be analysed: C1,C2,C3,C4,H2,CO2,∑C
|
| |
|
 |
|
| |
|
Natural Gas Analytical Gas Chromatography  |
|
Natural Gas Analytical Gas Chromatography is a new type special chromatography developed and designed on the basis of introducing and assimilating GC3400 manufacturing technology from American Varian Company, and it keeps all the functions of GC3400 gas chromatography. The machine adopts packed column, quartz capillary multidimensional column, valve switch systems, and a single injection can conduct fast analysis on O2,N2,CH4,CO2,C20,C30,iC40,nC40,iC50,nC50,iC60,nC60 and other ingredients, it can analyze hydrocarbon substances as high as C12. Its analysis speed is fast, and it can finish the analysis of the modulate compounds less than C6 within seven minutes.
The machine adopts the latest automatic switch valve design. The valve is easy to operate, and without extra-column volume effect and only one valve operation is required for each analytical cycle so that it reduces the times of the operation. Thus, the valve’s life-span could reach over 100000 times. There are four external event program operations, and all valves and the detector signals are automatically switched by the pre-set programs. It can work with all kinds of common chromatogram data workstations and conduct fast computation on the chromatogram. The original data could be stored permanently and it could be accessed and reprocessed at any time. |
Technical parameters:
- Column box temperature: above room temperature (20-350℃)
- Temperature programming: 1-4 level linear temperature programming can be set, the rate is 0.1-50℃/min.
- Detector temperature: above room temperature (20-350℃)
- Injector temperature: above room temperature (20-350℃)
- Valve box temperature: 50℃
- TCD sensitivity: ≥5000mvml/mg(sample butane)
- FID detecting limit :≤ 8 × 10-12g/s(N-C16)
- Ingredients to be analysed: O2,N2,CH4,CO2,C2-C12
|
| |
|
 |
|
| |
|
Liquid Oxygen Hydrocarbon Compound Gas Chromatography  |
| In the production procedure of steel mills and petroleum & chemical plants, the gas separation equipment is an important part of the whole procedure. The working principle of the gas separation equipment is to gradually condense the concentration into liquid oxygen from the hydrocarbon compound in the air, and when the concentration of the hydrocarbon compound reach its limit, it can lead to cold explosion and cause series accident. In order to ensure the safe operation of gas separation equipment, it is necessary to check the ingredients and contents of the hydrocarbon compound in the liquid oxygen, and to identify the equipment fault in its early stage so as to take measures to deal with the problem, by doing so, it can avoid occurrence of the series accident and reduce the unnecessary loss.
To satisfy the needs of the domestic users, our company has developed Special Liquid Oxygen Hydrocarbon Compound Gas Chromatogram System. The system is equipped with high sensitivity flamboyance detection chromatography by introducing American technologies, imported chromatogram column and six routes automatic injection valves, professional chromatogram analytical workstation, and calibration standard gas. It can conduct the fast analysis on C1-C4 (CH4C2H4C2H6C2H2C3H6C3H8C4H8C4H10) ingredients, and the inspection result could be directly displayed and printed. The key components and parts are provided by the American VARIAN Company and other international manufactures with famous brands. It is a high performance product with complete functions, and it is reliable and easy to operate. |
Technical parameters:
- Column box temperature range: Room temperature to 350℃
- Temperature programming: one level or multi-level linear temperature programming can be set, the rate is 0.1-50 ℃ /min.
- Detector temperature: Room temperature to 350℃
- Injector temperature: Room temperature to 350℃
- FID detecting limit:≤8×10-12g/s(N-G16)
- It can conduct automatic analysis with a single injection on ingredients such as
CH4,C2H2,C2H4,C2H8,C3H8,C3H6, and etc.
- The minimum C2H2 detection concentration: ≤0.5ppm
|
| |
|
 |
| |
|
|
|
|